Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.921
Filtrar
1.
Biomater Adv ; 159: 213823, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38460353

RESUMO

Lung cancer, one of the most common causes of high mortality worldwide, still lacks appropriate and convenient treatment options. Photodynamic therapy (PDT) has shown promising results against cancer, especially in recent years. However, pulmonary drug delivery of the predominantly hydrophobic photosensitizers still represents a significant obstacle. Nebulizing DPPC/Cholesterol liposomes loaded with the photosensitizer curcumin via a vibrating mesh nebulizer might overcome current restrictions. In this study, the liposomes were prepared by conventional thin-film hydration and two other methods based on dual centrifugation. The liposomes' physicochemical properties were determined before and after nebulization, showing that liposomes do not undergo any changes. However, morphological characterization of the differently prepared liposomes revealed structural differences between the methods in terms of lamellarity. Internalization of curcumin in lung adenocarcinoma (A549) cells was visualized and quantified. The generation of reactive oxygen species because of the photoreaction was also proven. The photodynamic efficacy of the liposomal formulations was tested against A549 cells. They revealed different phototoxic responses at different radiant exposures. Furthermore, the photodynamic efficacy was investigated after nebulizing curcumin-loaded liposomes onto xenografted tumors on the CAM, followed by irradiation, and evaluated using positron emission tomography/computed tomography and histological analysis. A decrease in tumor metabolism could be observed. Based on the efficacy of curcumin-loaded liposomes in 2D and 3D models, liposomes, especially with prior film formation, can be considered a promising approach for PDT against lung cancer.


Assuntos
Curcumina , Neoplasias Pulmonares , Humanos , Lipossomos/uso terapêutico , Curcumina/farmacologia , Curcumina/uso terapêutico , Sistemas de Liberação de Medicamentos , Nebulizadores e Vaporizadores , Fármacos Fotossensibilizantes/uso terapêutico , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/patologia
2.
AAPS PharmSciTech ; 25(2): 36, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38356031

RESUMO

Pulmonary drug delivery is a form of local targeting to the lungs in patients with respiratory disorders like cystic fibrosis, pulmonary arterial hypertension (PAH), asthma, chronic pulmonary infections, and lung cancer. In addition, noninvasive pulmonary delivery also presents an attractive alternative to systemically administered therapeutics, not only for localized respiratory disorders but also for systemic absorption. Pulmonary delivery offers the advantages of a relatively low dose, low incidence of systemic side effects, and rapid onset of action for some drugs compared to other systemic administration routes. While promising, inhaled delivery of therapeutics is often complex owing to factors encompassing mechanical barriers, chemical barriers, selection of inhalation device, and limited choice of dosage form excipients. There are very few excipients that are approved by the FDA for use in developing inhaled drug products. Depending upon the dosage form, and inhalation devices such as pMDIs, DPIs, and nebulizers, different excipients can be used to provide physical and chemical stability and to deliver the dose efficiently to the lungs. This review article focuses on discussing a variety of excipients that have been used in novel inhaled dosage forms as well as inhalation devices.


Assuntos
Asma , Excipientes , Humanos , Excipientes/farmacologia , Administração por Inalação , Nebulizadores e Vaporizadores , Asma/tratamento farmacológico , Pulmão , Preparações Farmacêuticas
3.
Int J Pharm ; 648: 123569, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37925043

RESUMO

A challenge in pressurised metered-dose inhaler (pMDI) formulation design is management of adhesion of the drug to the canister wall, valve and actuator internal components and surfaces. Wall-material interactions differ between transparent vials used for visual inspection and metal canister pMDI systems. This is of particular concern for low greenhouse warming potential (GWP) formulations where propellant chemistry and solubility with many drugs are not well understood. In this study, we demonstrate a novel application of X-ray fluorescence spectroscopy using synchrotron radiation to assay the contents of surrogate solution and suspension pMDI formulations of potassium iodide and barium sulphate in propellants HFA134a, HFA152a and HFO1234ze(E) using aluminium canisters and standard components. Preliminary results indicate that through unit life drug distribution in the canister valve closure region and actuator can vary significantly with new propellants. For solution formulations HFO1234ze(E) propellant shows the greatest increase in local deposition inside the canister valve closure region as compared to HFA134a and HFA152a, with correspondingly reduced actuator deposition. This is likely driven by chemistry changes. For suspension formulations HFA152a shows the greatest differences, due to its low specific gravity. These changes must be taken into consideration in the development of products utilising low-GWP propellants.


Assuntos
Inaladores Dosimetrados , Nebulizadores e Vaporizadores , Administração por Inalação , Cateteres , Alumínio , Suspensões , Propelentes de Aerossol/química , Hidrocarbonetos Fluorados/química
4.
Cochrane Database Syst Rev ; 11: CD007639, 2023 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-37942828

RESUMO

BACKGROUND: Nebuliser systems are used to deliver medications to the lungs, to control the symptoms and the progression of lung disease in people with cystic fibrosis (CF). There are many different nebulised-medications prescribed for people with CF and there are many different types of nebuliser systems. Some of these nebulised medications are licenced for, and can be taken via only one type of nebuliser system; some are licensed for, and can be taken via more than one type of nebuliser system. This is an update to a previous systematic review. OBJECTIVES: To assess the time efficiency, effectiveness, safety, cost and impact of use (e.g. burden of care, adherence, quality of life (QoL)) of different nebuliser systems, when used with different inhaled medications for people with CF. SEARCH METHODS: We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches, handsearching of relevant journals and abstract books containing conference proceedings. We searched the reference lists of each study for additional publications and approached the manufacturers of both nebuliser systems and nebulised medications for published and unpublished data. We also searched online trial registries. Date of the most recent search: 9 August 2023. SELECTION CRITERIA: Randomised controlled trials (RCTs) or quasi-RCTs comparing nebuliser systems, including conventional nebulisers, vibrating mesh technology (VMT) systems, adaptive aerosol delivery (AAD) systems and ultrasonic nebuliser systems. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed studies for inclusion. They also independently extracted data and assessed the risk of bias. A third review author assessed studies where agreement could not be reached. They assessed the certainty of the evidence using GRADE. MAIN RESULTS: The search identified 216 studies with 33 of these (2270 participants) included in the review. These studies compared the delivery of tobramycin, colistin, dornase alfa, hypertonic saline and other solutions through the different nebuliser systems in children and adults with CF. This review demonstrates variability in the delivery of medication depending on the nebuliser system used. The certainty of the evidence ranged from low to very low. Some conventional nebuliser systems providing higher flows, higher respirable fractions, and smaller particles decrease treatment time, increase deposition (the amount of drug reaching the lung), and may be preferred by people with CF, as compared to other conventional nebuliser systems providing lower flows, lower respirable fractions and larger particles. Newer nebuliser systems using AAD, or VMT (or both) reduce treatment time compared to conventional systems. Deposition (as a percentage of priming dose) with AAD is greater than with conventional systems. VMT systems may give greater deposition than conventional systems when measuring sputum levels. The available data indicate that these newer systems are safe when used with an appropriate priming dose, which may be different to the priming dose used for conventional systems. There is an indication that adherence is maintained or improved and that individuals prefer AAD or VMT systems, but also that some nebuliser systems using VMT may be subject to increased system failures. There is limited, unclear evidence on the impact of different nebuliser systems on lung function and a lack of data on the impact of different nebuliser systems on our outcomes of quality of life (QoL), adverse effects, respiratory exacerbations and related implications, adherence, satisfaction, cost and device reliability. AUTHORS' CONCLUSIONS: Newer technologies e.g. AAD and VMT have advantages over conventional systems in terms of treatment time, deposition as a percentage of priming dose, preference and adherence. Data are lacking for all varieties of medications which are used in CF care, including different inhaled antibiotics or hypertonic saline, with all delivery (nebuliser system) possibilities. Long-term RCTs are needed to evaluate different nebuliser systems to determine patient-focused outcomes (such as QoL and burden of care), safe and effective dosing levels of a wide variety of medications, clinical outcomes (such as hospitalisations and need for antibiotics), and an economic evaluation of their use. There are insufficient data to establish whether one nebuliser system is better than another overall. Clinicians should be aware of the variability in the performance of different nebuliser systems, compatibility with specific nebulised medication, and they must work with their patients to choose the best nebuliser system for each individual. This is likely to be an ongoing process as the needs and circumstances of each individual change over time.


Assuntos
Fibrose Cística , Criança , Adulto , Humanos , Fibrose Cística/tratamento farmacológico , Aerossóis e Gotículas Respiratórios , Antibacterianos/uso terapêutico , Nebulizadores e Vaporizadores , Tobramicina/uso terapêutico , Solução Salina Hipertônica/uso terapêutico
5.
BMC Pulm Med ; 23(1): 447, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37978359

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the inhaler skills of patients with asthma and chronic obstructive pulmonary disease in a hospital in western China after receiving one medication education by pharmacists and the factors related to these skills. METHODS: We included 96 subjects using Turbuhaler and 74 subjects using Diskus in a hospital in western China. They were educated once by pharmacists before medication, and then their skills of operating these inhalers were visually evaluated the next time they were used. Using the seven-step inhalation administration method designed by AnnaMurphy, a clinical pharmacist at GLENFIELD Hospital in the UK, the inhaler use technique score scale was established and scored in turn. The age, sex, time of first illness, smoking status, education level and type of health insurance purchased by each patient were recorded to assess their relationship with overall inhaler skills. RESULTS: 19.8% of the subjects who used Turbuhaler could not use it correctly, and 43.2% of the subjects who used Diskus could not use it correctly. The step with the highest error rate with Turbuhaler and Diskus is to "exhale slowly to residual volume". Chi-square test was carried out for each step of the operation of the two kinds of inhalers, and it was found that there was a significant difference in the operation accuracy of the two kinds of inhalers in the first, third and eighth steps. In univariate analysis, advanced age, female and low educational level were related to the lack of inhaler technology, but in multivariate analysis, only low educational level was a significant independent risk factor. CONCLUSION: Among the patients with asthma and chronic obstructive pulmonary disease in western China, some patients have good inhaler operation skills, but there are still many patients who can not use inhalers correctly, and the lower education level is significantly related to the incorrect use of inhalers.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Humanos , Feminino , Nebulizadores e Vaporizadores , Asma/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Administração por Inalação , China
6.
J Am Heart Assoc ; 12(23): e032969, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38014661

RESUMO

BACKGROUND: Marijuana leaf vaporizers, which heat plant material and sublimate Δ-9-tetrahydrocannabinol without combustion, are popular alternatives to smoking cannabis that are generally perceived to be less harmful. We have shown that smoke from tobacco and marijuana, as well as aerosol from e-cigarettes and heated tobacco products, impair vascular endothelial function in rats measured as arterial flow-mediated dilation (FMD). METHODS AND RESULTS: We exposed 8 rats per group to aerosol generated by 2 vaporizer systems (Volcano and handheld Yocan) using marijuana with varying Δ-9-tetrahydrocannabinol levels, in a single pulsatile exposure session of 2 s/min over 5 minutes, and measured changes in FMD. To model secondhand exposure, we exposed rats for 1 minute to diluted aerosol approximating release of uninhaled Volcano aerosol into typical residential rooms. Exposure to aerosol from marijuana with and without cannabinoids impaired FMD by ≈50%. FMD was similarly impaired by aerosols from Yocan (237 °C), and from Volcano at both its standard temperature (185 °C) and the minimum sublimation temperature of Δ-9-tetrahydrocannabinol (157 °C), although the low-temperature aerosol condition did not effectively deliver Δ-9-tetrahydrocannabinol to the circulation. Modeled secondhand exposure based on diluted Volcano aerosol also impaired FMD. FMD was not affected in rats exposed to clean air or water vapor passed through the Volcano system. CONCLUSIONS: Acute direct exposure and modeled secondhand exposure to marijuana leaf vaporizer aerosol, regardless of cannabinoid concentration or aerosol generation temperature, impair endothelial function in rats comparably to marijuana smoke. Our findings indicate that use of leaf vaporizers is unlikely to reduce the vascular risk burden of smoking marijuana.


Assuntos
Canabinoides , Cannabis , Sistemas Eletrônicos de Liberação de Nicotina , Fumar Maconha , Ratos , Animais , Dronabinol , Nebulizadores e Vaporizadores , Aerossóis , Fumar Maconha/efeitos adversos , Fumaça , Dilatação Patológica , Folhas de Planta
7.
Sensors (Basel) ; 23(19)2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37837050

RESUMO

To study and monitor the adverse health consequences of using electronic cigarettes, a user's puff topography, which are quantification parameters of the user's vaping habits, plays a central role. In this work, we introduce a topography sensor to measure the mass of total particulate matter generated in every puff and to estimate the nicotine yield. The sensor is compact and low-cost, and is integrated into the electronic cigarette device to promptly and conveniently monitor the user's daily puff topography. The topography sensor is comprised of a photometric sensor and a pressure sensor. The photometric sensor measures the mass concentration of the aerosol, based on scattering of near-infrared light from airborne particles, while the pressure sensor measures the flow rate. The topography sensor was tested under various conditions including a wide range of atomizer power, puff duration, and inhalation pressure. The sensor's accuracy was validated by comparing the sensor's readings with reference measurements, and the results matched closely with the trends reported by existing studies on electronic cigarettes. An example application for tracking a user's puff topography was also demonstrated. Our topography sensor holds great promise in mitigating the health risks of vaping, and in promoting quality control of electronic cigarette products.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Vaping , Nicotina , Aerossóis , Nebulizadores e Vaporizadores
8.
Eur J Pharm Sci ; 191: 106606, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37832856

RESUMO

Non-Human Primates (NHPs) are particularly relevant for preclinical studies during the development of inhaled biologics. However, aerosol inhalation in NHPs is difficult to evaluate due to a low lung deposition fraction and high variability. The objective of this study was to evaluate the influence of mesh nebulizer parameters to improve lung deposition in macaques. We developed a humidified heated and ventilated anatomical 3D printed macaque model of the upper respiratory tract to reduce experiments with animals. The model was compared to in vivo deposition using 2D planar scintigraphy imaging in NHPs and demonstrated good predictivity. Next, the anatomical model was used to evaluate the position of the nebulizer on the mask, the aerosol particle size and the aerosol flow rate on the lung deposition. We showed that placing the mesh-nebulizer in the upper part of the mask and in proximal position to the NHP improved lung delivery prediction. The lower the aerosol size and the lower the aerosol flow rate, the better the predicted aerosol deposition. In particular, for 4.3 ± 0.1 µm in terms of volume mean diameter, we obtained 5.6 % ± 0.2 % % vs 19.2 % ± 2.5 % deposition in the lung model for an aerosol flow rate of 0.4 mL/min vs 0.03 mL/min and achieved 16 % of the nebulizer charge deposited in the lungs of macaques. Despite the improvement of lung deposition efficiency in macaques, its variability remained high (6-21 %).


Assuntos
Nebulizadores e Vaporizadores , Animais , Administração por Inalação , Aerossóis , Albuterol , Broncodilatadores , Desenho de Equipamento , Pulmão , Macaca , Primatas
9.
BMJ Open Respir Res ; 10(1)2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37730281

RESUMO

INTRODUCTION: Climate change from greenhouse gas (GHG) emissions represents one of the greatest public health threats of our time. Inhalers (and particularly metred-dose inhalers (MDIs)) used for asthma and chronic obstructive pulmonary disease (COPD), constitute an important source of GHGs. In this analysis, we aimed to estimate the carbon footprint impact of improving three distinct aspects of respiratory care that drive avoidable inhaler use in Canada. METHODS: We used published data to estimate the prevalence of misdiagnosed disease, existing inhaler use patterns, medication class distributions, inhaler type distributions and GHGs associated with inhaler actuations, to quantify annual GHG emissions in Canada: (1) attributable to asthma and COPD misdiagnosis; (2) attributable to overuse of rescue inhalers due to suboptimally controlled symptoms; and (3) avoidable by switching 25% of patients with existing asthma and COPD to an otherwise comparable therapeutic option with a lower GHG footprint. RESULTS: We identified the following avoidable annual GHG emissions: (1) ~49 100 GHG metric tons (MTs) due to misdiagnosed disease; (2) ~143 000 GHG MTs due to suboptimal symptom control; and (3) ~262 100 GHG MTs due to preferential prescription of strategies featuring MDIs over lower-GHG-emitting options (when 25% of patients are switched to lower GHG alternatives). Combined, the GHG emission reductions from bridging these gaps would be the equivalent to taking ~101 100 vehicles off the roads each year. CONCLUSIONS: Our analysis shows that the carbon savings from addressing misdiagnosis and suboptimal disease control are comparable to those achievable by switching one in four patients to lower GHG-emitting therapeutic strategies. Behaviour change strategies required to achieve and sustain delivery of evidence-based real-world care are complex, but the added identified incentive of carbon footprint reduction may in itself prove to be a powerful motivator for change among providers and patients. This additional benefit can be leveraged in future behaviour change interventions.


Assuntos
Asma , Gases de Efeito Estufa , Doença Pulmonar Obstrutiva Crônica , Humanos , Asma/diagnóstico , Asma/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Nebulizadores e Vaporizadores , Canadá
10.
Int J Chron Obstruct Pulmon Dis ; 18: 1931-1935, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37675197

RESUMO

The risk of foreign body aspiration associated with uncapped handheld metered-dose inhalers (MDIs) is underestimated. We report a case in which a plastic cable clip accidentally lodged in the mouthpiece of an uncapped pressurized MDI was aspirated during its use. A literature search revealed 16 other cases of foreign body aspiration associated with uncapped handheld inhalers, all but one of which were pressurized inhalers. Patients should be informed of the risk of foreign body aspiration associated with uncapped pocket inhalers. The use of an uncuffed armoured tracheal tube with a separate oxygen tubing during flexible bronchoscopy for foreign body removal ensures a safe airway. Foreign bodies that exceed the lumen size of the tracheal tube can be pulled to the distal opening with forceps and removed when the tube is withdrawn.


Assuntos
Corpos Estranhos , Doença Pulmonar Obstrutiva Crônica , Humanos , Inaladores Dosimetrados , Nebulizadores e Vaporizadores , Broncoscopia/efeitos adversos , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia
11.
Adv Ther ; 40(11): 4836-4856, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37684493

RESUMO

INTRODUCTION: Healthcare systems are looking to reduce their carbon impact. Short-acting ß2-agonist (SABA) overuse (≥ 3 canisters/year) is common in asthma and linked to poor outcomes; however, its environmental impact remains unknown. As part of the CARBON programme, this study retrospectively quantified the carbon footprint of SABA and controller inhalers across all respiratory indications and SABA overuse in asthma in lower-middle-income countries (LMICs), upper-middle-income countries and high-income countries across Africa, Asia Pacific, Latin America and the Middle East. METHODS: Two data sources were utilised to evaluate the carbon contribution of inhalers to respiratory care. To quantify greenhouse gas (GHG) emissions associated with total inhaler use across all respiratory indications, inhaler sales data were obtained from IQVIA MIDAS® (Q4/2018-Q3/2019) and compared by dose to prevent confounding from differences in canister actuation counts. GHG emissions associated with SABA overuse in asthma were evaluated using prescription and self-reported over-the-counter purchase data from the SABA use IN Asthma (SABINA) III study (2019-2020). Inhaler-related GHG emissions were quantified using published data and product life cycle assessments. RESULTS: SABA accounted for > 50% of total inhaler use and inhaler-related emissions in most countries analysed. The total SABA-related emissions were estimated at 2.7 million tonnes carbon dioxide equivalents, accounting for 70% of total inhaler-related emissions. Among the countries, regions and economies analysed, per capita SABA use and associated emissions were higher in Australia, the Middle East and high-income countries. Most SABA prescriptions for asthma (> 90%) were given to patients already overusing SABA. CONCLUSIONS: Globally, SABA use/overuse is widespread and is the greatest contributor to the carbon footprint of respiratory treatment, regardless of the economic status of countries. Implementing evidence-based treatment recommendations, personalising treatment and reducing healthcare inequities, especially in LMICs, may improve disease control and patient outcomes, thereby reducing SABA overuse and associated carbon emissions beyond SABA use alone.


The healthcare sector is a large emitter of greenhouse gases (GHGs); therefore, healthcare systems will need to reduce their carbon footprint to meet their carbon reduction targets. In respiratory care, the environmental impact of controller inhalers has received considerable attention due to the global warming potential of the propellants used in metered-dose inhalers. In contrast, little is known about the contribution made by short-acting ß2-agonist (SABA) relievers globally, which are often the only inhaled medication used by many patients with milder asthma. The SABA use IN Asthma (SABINA) programme reported that SABA overuse (3 or more SABA canisters/year) is common and associated with an increased risk of asthma attacks. Since all inhalers have a carbon footprint, SABA overuse may result in an avoidable excess carbon footprint. Therefore, to provide a complete picture of the carbon footprint of respiratory care, we examined the contribution of SABA relievers and their potential overuse. The total SABA-related GHG emissions accounted for 70% of total inhaler-related GHG emissions, and > 90% of prescriptions for SABA relievers for asthma were given to patients who were already overusing their SABA. Overall, SABA use/overuse is commonly observed worldwide and is likely a significant contributor to the carbon footprint of respiratory treatment. Therefore, there is an urgent need for healthcare providers to follow the latest international treatment guidelines to reduce high SABA use in respiratory care and improve patient outcomes. This, in turn, will enable healthcare systems to reduce their carbon footprint from both treatment and patient interactions.


Assuntos
Asma , Gases de Efeito Estufa , Humanos , Estudos Retrospectivos , Asma/tratamento farmacológico , Nebulizadores e Vaporizadores , Administração por Inalação
12.
Respir Med Res ; 84: 101038, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37734235

RESUMO

INTRODUCTION: Nebulization plays a key role in the treatment of cystic fibrosis. The Favorite function couple to jet nebulizers (AKITA®) emerged recently. The aim of this study was to assess the efficiency of the lung delivery by the AKITA® by comparing the urinary concentration of amikacin after nebulization with the AKITA® and the eFlow rapid®, in healthy subjects and patients with CF (PwCF). METHOD: The two samples (healthy subjects and PwCF) were randomized (cross-over 1:1) for two nebulizations (500 mg of amikacin diluted in 4 mL of normal saline solution), with the AKITA® and with the eFlow rapid®. The primary endpoint was the amount of urinary excretion of amikacin over 24 h. The constant of elimination (Ke) was calculated based on the maximal cumulative urinary amikacin excretion plotted over time. RESULTS: The total amount of urinary amikacin excretion was greater when AKITA® was used in PwCF (11.7 mg (8.2-14.1) vs 6.1 mg (3.7-13.3); p = 0.02) but not different in healthy subjects (14.5 mg (11.7-18.5) vs 12.4 mg (8.0-17.1); p = 0.12). The duration of the nebulization was always shorter with eFlow rapid® than with AKITA® (PwCF: 6.5 ± 0.6 min vs 9.2 ± 1.8 min; p = 0.001 - Healthy: 4.7 ± 1.3 min vs 9.7 ± 1.6 min; p = 0.03). The constant of elimination was similar between the two modalities in CF subjects (0.153 (0.071-0.205) vs 0.149 (0.041-0.182); p = 0.26) and in healthy subjects (0.166 (0.130-0.218) vs 0.167 (0.119-0.210), p = 0.25). CONCLUSION: the Favorite inhalation is better to deliver a specific amount of drug than a mesh nebulizer (eFlow rapid®) in PwCF but not in healthy subjects.


Assuntos
Amicacina , Antibacterianos , Humanos , Amicacina/urina , Estudos Cross-Over , Aerossóis e Gotículas Respiratórios , Nebulizadores e Vaporizadores , Pulmão
13.
J Med Internet Res ; 25: e46153, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37552552

RESUMO

BACKGROUND: Inhaling aerosolized nicotine and cannabis (colloquially called "vaping") is prevalent among young adults. Instagram influencers often promote both nicotine and cannabis vaporizer products. However, Instagram posts discouraging the use of both products received national media attention during the 2019 outbreak of e-cigarette or vaping-associated lung injury (EVALI). OBJECTIVE: This experiment tested the impact of viewing Instagram posts about EVALI, varying in image and text valence, on young adults' perceived harmfulness of nicotine and cannabis products, perceived risk of nicotine and cannabis vaporizer use, and intentions to use nicotine and cannabis vaporizers in the future. METHODS: Participants (N=1229) aged 18-25 (mean 21.40, SD 2.22) years were recruited through Qualtrics Research Services, oversampling for ever-use of nicotine or cannabis vaporizers (618/1229, 50.3%). Participants were randomly assigned to view Instagram posts from young people portraying their experiences of EVALI in a 2 (image valence: positive or negative) × 2 (text valence: positive or negative) between-subjects experiment. Positive images were attractive and aesthetically pleasing selfies. The positive text was supportive and uplifting regarding quitting the use of vaporized products. Negative images and text were graphic and fear inducing. After viewing 3 posts, participants reported the perceived harmfulness of nicotine and cannabis products, the perceived risk of nicotine and cannabis vaporizer use, and intentions to use nicotine and cannabis vaporizers in the future. Ordinal logistic regression models assessed the main effects and interactions of image and text valence on perceived harmfulness and risk. Binary logistic regression models assessed the main effects and interactions of image and text valence on intentions to use nicotine and cannabis vaporizers. Analyses were adjusted for product use history. RESULTS: Compared to viewing positive images, viewing negative images resulted in significantly greater perceived harm of nicotine (P=.02 for disposable pod-based vaporizers and P=.04 for other e-cigarette "mods" devices) and cannabis vaporized products (P=.01), greater perceived risk of nicotine vaporizers (P<.01), and lower odds of intentions to use nicotine (P=.02) but not cannabis (P=.43) vaporizers in the future. There were no significant main effects of text valence on perceived harm, perceived risk, and intentions to use nicotine and cannabis vaporized products. No significant interaction effects of image and text valence were found. CONCLUSIONS: Negative imagery in Instagram posts about EVALI may convey the risks of vaporized product use and discourage young adults from this behavior, regardless of the valence of the post's text. Public health messaging regarding EVALI on Instagram should emphasize the risk of cannabis vaporizer use, as young adults may otherwise believe that only nicotine vaporizer use increases their risk for EVALI.


Assuntos
Cannabis , Sistemas Eletrônicos de Liberação de Nicotina , Lesão Pulmonar , Humanos , Adulto Jovem , Adolescente , Adulto , Nicotina , Lesão Pulmonar/etiologia , Lesão Pulmonar/epidemiologia , Intenção , Nebulizadores e Vaporizadores
14.
J Pharm Biomed Anal ; 234: 115553, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37399700

RESUMO

A novel simple, specific, sensitive, accurate and precise reversed phase high performance liquid chromatographic method (RP-HPLC/UV) was developed and validated for the simultaneous estimation of Glycopyrronium bromide (GLY), Indacaterol acetate (IND) and Mometasone furoate (MOF) in pure form, in laboratory prepared mixtures and in pharmaceutical dosage form. Experimental design methodology was applied by using Plackett-Burman and face-centered composite designs to achieve the best resolution with minimum experimental trials. The designed model was statistically analyzed, graphically presented by surface plots and the relationships between coefficients of the derived polynomial equations were interpreted. Chromatographic separation was achieved on Inertsil ODS C18 column (250 ×4.6 mm, 5 µm) at ambient temperature using a mobile phase composed of methanol: 0.1% glacial acetic acid (pH4) in a gradient elution at a flow rate 1 mL /min. UV detection was carried out at 233 nm. Response was found to be linear in the concentration range of 20-120 µg /mL with regression coefficient (r2 = 0.999) for GLY, 50-300 µg /mL with regression coefficient (r2 = 0.9995) for IND and 50-300 µg /mL with regression coefficient (r2 = 0.9998) for MOF. The method was validated as per ICH guidelines and satisfactory results were achieved. The method was successfully applied for the analysis of the cited drugs in their fixed dose combination (FDC) pharmaceutical formulation. Statistical comparison between the results obtained by the proposed method and the reference methods for GLY, IND and MOF showed no significant difference. The developed method could be implemented in quality control aspects of the cited drugs. Four green metrics were used to evaluate the new RP-HPLC/UV method's greenness and compare it to other published techniques.


Assuntos
Glicopirrolato , Quinolonas , Furoato de Mometasona , Cromatografia Líquida de Alta Pressão/métodos , Nebulizadores e Vaporizadores
15.
Thorax ; 78(10): 1011-1018, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37451864

RESUMO

INTRODUCTION: People with cystic fibrosis (CF) are often on multiple long-term treatments, including mucoactive nebulisers. In the UK, the most common mucoactive nebuliser is dornase alfa (DNase). A common therapeutic approach for people already on DNase is to add hypertonic saline (HS). The effects of DNase and HS used alone have been studied in randomised trials, but their effects in combination have not. This study investigates whether, for people already prescribed DNase, adding HS has additional benefit for lung function or use of intravenous antibiotics. METHODS: Using UK CF Registry data from 2007 to 2018, we emulated a target trial. We included people aged 6 years and over who were prescribed DNase without HS for 2 years. We investigated the effects of combinations of DNase and HS over 5 years of follow-up. Inverse-probability-of-treatment weighting was used to control confounding. The period predated triple combination CF transmembrane conductance regulator modulators in routine care. RESULTS: 4498 individuals were included. At baseline, average age and forced expiratory volume in 1 s (FEV1%) predicted were 21.1 years and 69.7 respectively. During first year of follow-up, 3799 individuals were prescribed DNase alone; 426 added HS; 57 switched to HS alone and 216 were prescribed neither. We found no evidence that adding HS improved FEV1% at 1-5 years, or use of intravenous antibiotics at 1-4 years, compared with DNase alone. CONCLUSION: For individuals with CF prescribed DNase, we found no evidence that adding HS had an effect on FEV1% or prescription of intravenous antibiotics. Our study illustrates the emulated target trial approach using CF Registry data.


Assuntos
Fibrose Cística , Humanos , Fibrose Cística/tratamento farmacológico , Dados de Saúde Coletados Rotineiramente , Nebulizadores e Vaporizadores , Administração por Inalação , Volume Expiratório Forçado , Solução Salina Hipertônica/uso terapêutico
16.
Eur J Pharm Sci ; 189: 106522, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37423579

RESUMO

Recombinant human deoxyribonuclease I (rhDNase, Pulmozyme®) is the most frequently used mucolytic agent for the symptomatic treatment of cystic fibrosis (CF) lung disease. Conjugation of rhDNase to polyethylene glycol (PEG) has been shown to greatly prolong its residence time in the lungs and improve its therapeutic efficacy in mice. To present an added value over current rhDNase treatment, PEGylated rhDNase needs to be efficiently and less frequently administrated by aerosolization and possibly at higher concentrations than existing rhDNase. In this study, the effects of PEGylation on the thermodynamic stability of rhDNase was investigated using linear 20 kDa, linear 30 kDa and 2-armed 40 kDa PEGs. The suitability of PEG30-rhDNase to electrohydrodynamic atomization (electrospraying) as well as the feasibility of using two vibrating mesh nebulizers, the optimized eFlow® Technology nebulizer (eFlow) and Innospire Go, at varying protein concentrations were investigated. PEGylation was shown to destabilize rhDNase upon chemical-induced denaturation and ethanol exposure. Yet, PEG30-rhDNase was stable enough to withstand aerosolization stresses using the eFlow and Innospire Go nebulizers even at higher concentrations (5 mg of protein per ml) than conventional rhDNase formulation (1 mg/ml). High aerosol output (up to 1.5 ml per min) and excellent aerosol characteristics (up to 83% fine particle fraction) were achieved while preserving protein integrity and enzymatic activity. This work demonstrates the technical feasibility of PEG-rhDNase nebulization with advanced vibrating membrane nebulizers, encouraging further pharmaceutical and clinical developments of a long-acting PEGylated alternative to rhDNase for treating patients with CF.


Assuntos
Fibrose Cística , Aerossóis e Gotículas Respiratórios , Humanos , Animais , Camundongos , Estudos de Viabilidade , Nebulizadores e Vaporizadores , Administração por Inalação , Fibrose Cística/tratamento farmacológico , Polietilenoglicóis/uso terapêutico
17.
Respirology ; 28(9): 828-840, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37518933

RESUMO

The landscape of asthma has considerably changed in the last decade. Effective medications and inhaler devices have been developed and integrated into the asthma pharmacopoeia, but unfortunately, the proportion of uncontrolled patients remains unacceptably high. This is now recognized to be mainly due to the inappropriate use of medications or inhaler devices, heterogeneity of the disease or other factors contributing to the disease. Currently, inhaled corticosteroids (ICS), with or without long-acting beta agonists (LABA), are the cornerstone of asthma management, and recently international guidelines recognized the importance of combination inhaler therapy (ICS/LABA) even in mild asthma. In future, ultra-long-acting personalized medications and smart inhalers will complement combination inhaler therapy in order to effectively addresses issues such as adherence, inhaler technique and polypharmacy (both of drugs and devices). Asthma is now acknowledged as a multifaceted cluster of disorders and the treatment model has evolved from one-size-fits-all to precision medicine approaches such as treatable traits (TTs, defined as measurable and treatable clinically important factors) which encourages the quality use of medications and identification and management of all underlying behavioural and biological treatable risk factors. TT requires research and validation in a clinical context and the implementation strategies and efficacy in various settings (primary/secondary/tertiary care, low-middle income countries) and populations (mild/moderate/severe asthma) are currently evolving. Combination inhaler therapy and the TTs approach are complementary treatment approaches. This review examines the current status of personalized medicine and combination inhaler therapy, and describes futuristic views for these two strategies.


Assuntos
Asma , Humanos , Administração por Inalação , Asma/tratamento farmacológico , Nebulizadores e Vaporizadores , Corticosteroides/uso terapêutico , Quimioterapia Combinada
18.
Sci Rep ; 13(1): 11056, 2023 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-37422519

RESUMO

Successful aerosol therapy in mechanically ventilated patients depends on multiple factors. Among these, position of nebulizer in ventilator circuit and humidification of inhaled gases can strongly influence the amount of drug deposited in airways. Indeed, the main objective was to preclinically evaluate impact of gas humidification and nebulizer position during invasive mechanical ventilation on whole lung and regional aerosol deposition and losses. Ex vivo porcine respiratory tracts were ventilated in controlled volumetric mode. Two conditions of relative humidity and temperature of inhaled gases were investigated. For each condition, four different positions of vibrating mesh nebulizer were studied: (i) next to the ventilator, (ii) right before humidifier, (iii) 15 cm to the Y-piece adapter and (iv) right after the Y-piece. Aerosol size distribution were calculated using cascade impactor. Nebulized dose, lung regional deposition and losses were assessed by scintigraphy using 99mtechnetium-labeled diethylene-triamine-penta-acetic acid. Mean nebulized dose was 95% ± 6%. For dry conditions, the mean respiratory tract deposited fractions reached 18% (± 4%) next to ventilator and 53% (± 4%) for proximal position. For humidified conditions, it reached 25% (± 3%) prior humidifier, 57% (± 8%) before Y-piece and 43% (± 11%) after this latter. Optimal nebulizer position is proximal before the Y-piece adapter showing a more than two-fold higher lung dose than positions next to the ventilator. Dry conditions are more likely to cause peripheral deposition of aerosols in the lungs. But gas humidification appears hard to interrupt efficiently and safely in clinical use. Considering the impact of optimized positioning, this study argues to maintain humidification.


Assuntos
Ventilação não Invasiva , Animais , Suínos , Broncodilatadores , Nebulizadores e Vaporizadores , Aerossóis , Pulmão/diagnóstico por imagem , Administração por Inalação , Respiração Artificial , Gases , Desenho de Equipamento , Albuterol
19.
Sci Rep ; 13(1): 7330, 2023 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-37147394

RESUMO

Despite evidence demonstrating persistent lung function deficits in preterm-born children, especially in those who had bronchopulmonary dysplasia (BPD) in infancy, the underlying biological mechanisms explaining these lung function deficits remain poorly understood. We characterised the exhaled breath condensate (EBC) proteome in preterm-born children, with and without BPD; and before and after inhaler treatment. EBC from children aged 7-12 years, from the Respiratory Health Outcomes in Neonates (RHiNO) study, were analysed by Nano-LC Mass Spectrometry with Tandem Mass Tag labelling. Children with percent predicted forced expiratory volume in 1 second ≤ 85% were enrolled to a 12-week blinded randomised trial of inhaled corticosteroids alone (ICS) or with long-acting ß2-agonist (ICS/LABA) or placebo. EBC was analysed from 218 children at baseline, and 46 children received randomised inhaled therapy. 210 proteins were detected in total. For the 19 proteins present in every sample, the desmosome proteins: desmoglein-1, desmocollin-1 and plakoglobin were significantly decreased, and cytokeratin-6A was increased in preterm-born children with BPD when compared to preterm- and term-born controls. ICS/LABA treatment significantly increased abundance of desmoglein-1, desmocollin-1 and plakoglobin in the BPD group with low lung function, and significantly increased plakoglobin in those without BPD. No differences were noted after ICS treatment. Exploratory analyses of proteins not detected in all samples suggested decreased abundance of several antiproteases. This study provides proteomic evidence of ongoing pulmonary structural changes with decreased desmosomes in school-aged preterm-born children with BPD and low lung function, which was reversed with combined inhaled corticosteroids and long-acting ß2-agonists therapy.


Assuntos
Displasia Broncopulmonar , Recém-Nascido , Humanos , Criança , Displasia Broncopulmonar/tratamento farmacológico , Desmossomos , Desmocolinas , Proteômica , gama Catenina , Pulmão , Corticosteroides/uso terapêutico , Nebulizadores e Vaporizadores , Desmogleínas
20.
Adv Healthc Mater ; 12(22): e2300226, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37166052

RESUMO

Myriad lung diseases are life threatening and macrophages play a key role in both physiological and pathological processes. Macrophages have each pro-/anti-inflammatory phenotype, and each lung disease can be aggravated by over-polarized macrophage. Therefore, development of a method capable of mediating the macrophage phenotype is one of the solutions for lung disease treatment. For mediating the phenotype of macrophages, the pulmonary delivery system (PDS) is widely used due to its advantages, such as high efficiency and accessibility of the lungs. However, it has a low drug delivery efficiency ironically because of the perfect lung defense system consisting of the mucus layer and airway macrophages. In this study, zwitterion-functionalized poly(lactide-co-glycolide) (PLGA) inhalable microparticles (ZwPG) are synthesized to increase the efficiency of the PDS. The thin layer of zwitterions formed on PLGA surface has high nebulizing stability and show high anti-mucus adhesion and evasion of macrophages. As a reprogramming agent for macrophages, ZwPG containing dexamethasone (Dex) and pirfenidone (Pir) are treated to over-polarized M2 macrophages. As a result, a synergistic effect of Dex/Pir induces reprogramming of M2 macrophage to pro-inflammatory phenotypes.


Assuntos
Pneumopatias , Macrófagos , Humanos , Fenótipo , Pulmão , Nebulizadores e Vaporizadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA